XL Series Low Energy

XL-Series Low Energy RO Systems

AMI Small Commercial Low Energy Reverse Osmosis Systems

Designed to produce low dissolved solids water from tap or well water, these small commercial Low Energy RO systems use extra low energy XLE reverse osmosis membranes which run at 100–140 psi.

The product water is ideal for applications such as spot-free rinse, water stores, whole house systems, laboratories, ice makers, humidification, misting, and more.

Part of the L-series family (alongside L and HL series), these complete reverse osmosis systems are best suited for feed water with less than 1,000 PPM total dissolved solids (TDS).

The systems use proven, reliable components and are mounted on a sturdy powder-coated metal frame. Years of experience have shaped the design, ensuring optimal membrane life and minimizing fouling through smart process and fluid engineering.

XL-Series Reverse Osmosis System

Model No.

System Capacity

Qty. of 4×40 Membrane Elements (XLE)

Line Sizes
(NPT, Inches)

System Dimensions
(in/cm)

Approx. Shipping Weight
(Lb/Kg)

GPD

m³/day

Inlet

Perm.

Conc.

Length

Depth

Height

XL-14A-216

2,000

7.5

1

¾

½

½

20/51

28/71

54/137

275/125

XL-24A-216

4,000

15

2

¾

½

½

20/51

28/71

54/137

300/136

XL-34A-216

5,800

22

3

¾

½

½

20/51

28/71

54/137

325/147

XL-44A-216

7,500

28

4

¾

½

½

20/51

34/87

54/137

350/159

XL-54A-216

9,000

34

5

¾

½

½

20/51

34/87

54/137

375/170

XL-64A-216

10,000

38

6

¾

½

½

20/51

34/87

54/137

400/181

Notes and Voltage/ Ordering Information

  • All dimensions and weights are approximate.
  • Capacity Basis: 24 hrs/day
  • Systems rated at: 77°F (25°C) using 1,000 ppm sodium chloride solution operating at approx. 200 psi pressure. System capacity changes significantly with water temperature. For higher TDS a water analysis must be supplied and could result in modifications to the system or changing from XL to L or HL series system.
  • Minimum feed pressure to RO System: 40-60 PSI.
  • Chlorine must be removed with a carbon filter or with chemical injection prior to the RO system, if present in feed water.
  • Pretreatment for water hardness using a softener should be added to avoid scaling the membranes.
  • Feed water turbidity: Less than 1 NTU; Feed water silt density index (SDI): 3 maximum. If exceeded, pretreatment with media filter recommended. All pretreatment equipment and SDI test kits are available from Applied Membranes.
  • Voltage Codes: 216 = 220 -240v/ 1ph/ 60hz • 215 = 220-240v/1ph/50hz .
    Three phase or other voltages not available with XL Series. See Series L or HL.