Advantage Series

Request a Quote Ask a Question AMI’s Advantage Series RO Systems are designed to produce low dissolved solids product water from tap or well water. These systems use high efficiency, low energy membranes, and run at high recovery offering low maintenance and operational costs. They incorporate carbon filters for chlorine removal, and sediment pre-filtration prior to the RO for a packaged unit that is ready to run out of the box. Compact, Customizable and Expandable Low Maintenance and Low Operating Costs Fully Assembled and Ready to Run Request a Quote Ask a Question AMI’s Advantage Series RO Systems are designed to produce low dissolved solids product water from tap or well water. These systems use high efficiency, low energy membranes, and run at high recovery offering low maintenance and operational costs. They incorporate carbon filters for chlorine removal, and sediment pre-filtration prior to the RO for a packaged unit that is ready to run out of the box. Compact, Customizable and Expandable Low Maintenance and Low Operating Costs Fully Assembled and Ready to Run AMI’s Advantage Series RO Systems are designed to produce low dissolved solids product water from tap or well water. These systems use high efficiency, low energy membranes, and run at high recovery offering low maintenance and operational costs. They incorporate carbon filters for chlorine removal, and sediment pre-filtration prior to the RO for a packaged unit that is ready to run out of the box. Compact, Customizable and Expandable Low Maintenance and Low Operating Costs Fully Assembled and Ready to Run

Series P: 350 to 1,000 GPD Reverse Osmosis Systems

  • 10” Big Blue Carbon Block and 5 Micron Sediment Filter
  • 2.5” Diameter × 21” Length Thin Film Reverse Osmosis Membranes in SS Housings
  • RO System Dimensions: 21.75”L × 20”W × 33”H

P Series Advantage Commercial Reverse Osmosis RO Systems

Model No.*

RO System Capacity

RO Membrane Qty.

Connections

Approx. Shipping Weight (Lb/Kg)

GPD

m³/day

Inlet

Conc.

Perm.

P-125A

350

1.3

1

⅜”

⅜”

¼”

60

P-225A

700

2.7

2

⅜”

⅜”

¼”

65

P-325A

1,000

3.8

3

⅜”

⅜”

¼”

70

 

Series T: 600 to 1,700 GPD Reverse Osmosis Systems

  • 20” Big Blue Carbon Block and 5 Micron Sediment Filter
  • 2.5” Diameter × 40” Length Thin Film Reverse Osmosis Membranes in SS Housings
  • RO System Dimensions: 23”L × 24”W × 55”H

T Series Advantage Commercial Reverse Osmosis RO Systems

Model No.*

RO System Capacity

RO Membrane Qty.

Connections

Approx. Shipping Weight (Lb/Kg)

GPD

m³/day

Inlet

Conc.

Perm.

T-125A

600

2.0

1

¾”

½”

½”

95

T-225A

1,200

4.5

2

¾”

½”

½”

105

T-325A

1,700

6.4

3

¾”

½”

½”

115

 

Series M: 2,000 to 10,000 GPD Reverse Osmosis Systems

  • 20” Big Blue Carbon Block Filters (2) and 5 Micron Sediment Filter
  • 4” Diameter × 40” Length Thin Film Reverse Osmosis Membranes in SS Housings
  • RO System Dimensions: 35”L × 24”W × 55”H

M Series Advantage Commercial Reverse Osmosis RO Systems

Model No.*

RO System Capacity

RO Membrane Qty.

Connections

Approx. Shipping Weight (Lb/Kg)

GPD

m³/day

Inlet

Conc.

Perm.

M-14A

2,000

7.5

1

¾”

½”

½”

220

M-24A

4,000

15.0

2

¾”

½”

½”

235

M-34A

5,800

22.0

3

¾”

½”

½”

250

M-44A**

7,500

28.0

4

¾”

½”

½”

265

M-54A**

9,000

34.0

5

¾”

½”

½”

280

M-64A**

10,000

38.0

6

¾”

½”

½”

295

 

Voltage Code and RO System Notes

  • *Voltage: Please add our voltage codes to the end of the model number when ordering. Example: M-14A-116
    Voltage Codes:
    116= 110v, 1ph, 60hz
    • 216= 220/230v, 1ph, 60hz
    • 215 = 220/230v, 1ph, 50hz
    **M-44A, M-54A, and M-64A are available in 215 and 216 voltage only.   116 is not available for these models. 
  • Recommended Pre-Treatment Equipment: All pretreatment equipment and SDI test kits are available from Applied Membranes.
    Water Softener: Hardness must be removed if present in feed water prior to RO system to avoid scaling the membranes.
    Multimedia filter: If feed water exceeds <1 NTU turbidity, or silt density index (SDI) of 3, media filter pretreatment recommended.
  • Systems rated at: 77°F (25°C) using 1000 ppm sodium chloride solution operating at approx. 200 psi.
  • Capacity Basis: 24 hrs/day
  • Minimum feed pressure to RO System: 40-60 PSI.
    RO System capacity changes significantly with water temperature
  • All dimensions and weights are approximate.