Fleck 9000

Fleck 9000 & 9000SXT Series 1” Residential Twin Alternating Softener Control Valves

Fleck’s 9000 valve controls the regeneration of both tanks in a twin alternating softener and is ideal for twin residential or light commercial water softeners up to 16” diameter tank size.

Twin alternating softeners are metered for on-demand regeneration when a pre-set volume of water has been used. One resin tank is always in service while the other is in standby, helping maintain uninterrupted soft water flow.

Flow Rates: (50 PSI Inlet): 1” meter / ¾” meter. Continuous 21 gpm / 18 gpm, Peak 28 gpm / 24 gpm, Max Backwash 8.5 gpm / 8.5 gpm

  • Valve Material: Lead-Free Brass
  • 2½” – 8 NPSM Mounting Base
  • 1” In/Out Connections; ¾” or 1¼” connections also available
  • 1600 Brine System ⅜”
  • No Hard Water Bypass
  • Meter Immediate Regeneration

Available AMI model configurations:

AMI Model No. Valve Series Meter Size Operation Meter Capacity Range
YVS90EABAT03 9000 ¾” Mechanical 125–1,125 Gallon
YVS90FBBAT03 9000 1” Mechanical 1,550–26,350 Gallon
YVS90MABDT03 9000SXT ¾” Electronic Programmable 1–9,999 Gallon
YVS90MBBDT03 9000SXT 1” Electronic Programmable 1–9,999 Gallon
  • Valves shown 110v/60Hz; SXT valves are 24v/60Hz with 110v transformer; other voltages available.
  • Valves shown with 3 gpm backwash flow; other backwash flows are available up to 8.5 gpm.